Setra Systems Super Count Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Wagi kuchenne Setra Systems Super Count. Setra Systems Super Count Specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 73
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Setra Super Count
TM
Operator's Manual 1
Introduction
Thank you for purchasing a Setra Super Count scale. Its ease of operation and durable construction
should provide years of reliable service. While your scale is easy to operate, it is advisable to read
this guide carefully before use. It is designed to help you perform weighing, counting, and related
operations quickly and accurately.
This manual is divided into six sections. Section One, “Installing Your Scale,” explains the proper
installation of your scale. Section Two, “Understanding Your Scale,” explains the various keys, dis-
plays, and messages you will encounter while using your scale. Section Three, “Using Your Scale,”
provides the detailed instructions necessary to perform your scale’s various operations. Section Four,
“Advanced Functions” describes the use of the scale’s databases and using APWs in exponential
notation. Section Five “ScriptCoder” describes the scale’s programmable RS-232 output. The appen-
dices include setup information, calibration procedures, examples, a description of RS-232 commu-
nications, options and specifications.
Typographical Conventions used in this manual include the following:
1. bold lower case characters indicate specific keys on the scale keyboard.
(e.g. Press — tare. Asks you to press the key first and then the tare key on the scale
keyboard.)
2. “Quotation marks” enclose messages you receive from the scale display.
3. nnn indicates that a number will appear in the display message.
Przeglądanie stron 0
1 2 3 4 5 6 ... 72 73

Podsumowanie treści

Strona 1 - Introduction

Setra Super CountTM Operator's Manual 1IntroductionThank you for purchasing a Setra Super Count scale. Its ease of operation and dura

Strona 2 - Adjustable Foot

10 Setra Super CountTM Operator's ManualNOTE: a. A customized sample size may be preset by using the minimum sample size setup fea-ture. The

Strona 3 - Installing Your Scale

Setra Super CountTM Operator's Manual 11USING THE MINIMUM SAMPLE SIZE & ACCURACY FEATURECounting errors can be caused by non-unif

Strona 4 - EXPERIMENTATION

12 Setra Super CountTM Operator's Manual9. Wait for the “OK” symbol, then read the display. The scale now reads the total number ofpieces on

Strona 5 - Understanding Your Scale

Setra Super CountTM Operator's Manual 13COUNTING WITH A KNOWN AVERAGE-PIECE-WEIGHTThe scale can count the number of pieces in a lot b

Strona 6 - DISPLAY SYMBOLS

14 Setra Super CountTM Operator's ManualCOUNTING WITH ACCURACY ENHANCEMENTWhen counting parts that are not uniform in weight, you can period

Strona 7 - DISPLAY MESSAGES

Setra Super CountTM Operator's Manual 156. Remove pieces until the display reads the number of pieces you wish to count out or kit.7.

Strona 8 - Using Your Scale

16 Setra Super CountTM Operator's Manual3. Place the requested number of pieces on the pan. Press the count key. [To begin accumulat-ing cou

Strona 9

Setra Super CountTM Operator's Manual 17ENTERING, RECALLING & CLEARING ADDITIONAL ID ENTRIESA total of seven separate ID numbers

Strona 10 - Operator's Manual

18 Setra Super CountTM Operator's ManualPRINTING OUT INFORMATIONThe Super Count is designed to print out requested or stored information reg

Strona 11 - Setra Super Count

Setra Super CountTM Operator's Manual 19Section FourAdvanced FunctionsCOUNTING WITH APW VALUES IN EXPONENTIAL NOTATIONThe scale is ab

Strona 12 - COUNTING WITH A CONTAINER

2 Setra Super CountTM Operator's Manual FIGURE 1. Components and features of the Setra Super Count.Adjustable FootLevel BubbleKeypadDisplayW

Strona 13

20 Setra Super CountTM Operator's ManualCOUNTING WITH THE DATABASETo perform the following procedure the automatic APW/tare retrieval system

Strona 14 - REVERSE COUNTING OR KITTING

Setra Super CountTM Operator's Manual 212. Update the APW and/or tare, either by entering the values through the keyboard, bar code o

Strona 15

22 Setra Super CountTM Operator's ManualACCUMULATING COUNT BY IDTo accumulate the count by ID number, perform the following steps.1. Press t

Strona 16 - USE OF THE “INT” MODE

Setra Super CountTM Operator's Manual 23CLEARING THE ACCUMULATED COUNT OR WEIGHTThe count and weight accumulators are stored in non-v

Strona 17

24 Setra Super CountTM Operator's ManualCOUNT A BATCH OF WIDGETS AND RECORD THE TRANSACTIONThe inspector wants to count the number of widget

Strona 18 - PRINTING OUT INFORMATION

Setra Super CountTM Operator's Manual 25MULTIPLE IDENTICAL LABELSThe Super Count scale can be programmed to print the same label up t

Strona 19 - Advanced Functions

26 Setra Super CountTM Operator's ManualSection VScriptcoderTM Custom Label PrintingSetra Super Count scales with firmware 1.8 or higher, ca

Strona 20 - COUNTING WITH THE DATABASE

Setra Super CountTM Operator's Manual 27To program the script as the default label design, enter 0. This will program the scale to pr

Strona 21

28 Setra Super CountTM Operator's ManualPRINTING LABELS WITH SEQUENTIAL NUMBERINGThe Super Count scale can number packages sequentially (ex.

Strona 22 - ACCUMULATING WEIGHT BY ID

Setra Super CountTM Operator's Manual 29Appendix IUser-Definable UnitsIt is often convenient to weigh in user-defined units. Conversi

Strona 23

Setra Super CountTM Operator's Manual 3An Allen wrench and four socket head capscrews are provided to assist in the installation of t

Strona 24

30 Setra Super CountTM Operator's ManualAppendix IISetup FunctionsPRINT FORMATThe print format setup controls the printout of various measur

Strona 25 - INTERFACING WITH A COMPUTER

Setra Super CountTM Operator's Manual 317. Enter 1 if you wish to print the TARE weight (enter 0 if you do not).8. Press the setup/ca

Strona 26 - Custom Label Printing

32 Setra Super CountTM Operator's ManualPROGRAMMING A MINIMUM SAMPLE SIZEThis feature allows you to preset the minimum number of pieces that

Strona 27

Setra Super CountTM Operator's Manual 33PROGRAMMING BAUD RATE AND PARITYThe Setra Super Count is capable of interfacing with a wide v

Strona 28

34 Setra Super CountTM Operator's ManualDISPLAYING CAPACITY, SOFTWARE VERSION AND SETUP INFORMATIONSetra is continually making improvements

Strona 29 - User-Definable Units

Setra Super CountTM Operator's Manual 35To view the scale’s capacity, software version and to print current setup information, follow

Strona 30 - Setup Functions

36 Setra Super CountTM Operator's ManualSETTING THE TIME AND DATEYour Setra Super Count scale may be equipped with an optional time/date fea

Strona 31

Setra Super CountTM Operator's Manual 37UNITS ENABLE/DISABLE SELECTIONThe units enable/disable feature controls which weighing units

Strona 32

38 Setra Super CountTM Operator's ManualPIECE WEIGHT PER THOUSANDWhen counting extremely small parts, accuracy and efficiency can be increas

Strona 33 - DISPLAY HYSTERESIS

Setra Super CountTM Operator's Manual 397. The scale displays “SUrE ?.” This is a safety device to prevent you from accidentally eras

Strona 34

4 Setra Super CountTM Operator's ManualEXPERIMENTATION1. Display test...When your scale is first powered on, it automatically runs through a

Strona 35

40 Setra Super CountTM Operator's ManualCONTINUOUS PRINT MODEThe Super Count’s continuous print feature allows you to program the scale to p

Strona 36 - SETTING THE TIME AND DATE

Setra Super CountTM Operator's Manual 41Appendix IIICalibrationThe Setra Super Count is highly stable, and requires infrequent calibr

Strona 37

42 Setra Super CountTM Operator's ManualAppendix IVTypical Uses of Your ScaleTaring Out Box Weight Before Weighing FastenersTo fill an empty

Strona 38 - APW/TARE SCALE DATABASE SETUP

Setra Super CountTM Operator's Manual 43Kitting Microchips in Bags of 25To kit microchips in bags of 25, you need to know the averag

Strona 39

44 Setra Super CountTM Operator's ManualAppendix VGlossary of TermsACCURACYThe degree of conformity of a measured value to the true value.AV

Strona 40 - CONTINUOUS PRINT MODE

Setra Super CountTM Operator's Manual 45Appendix VIRS-232 Serial Data CommunicationsThe Setra Super Count comes equipped with a bi-di

Strona 41 - Calibration

46 Setra Super CountTM Operator's ManualTo redefine the command used for accessing the remote scale follow this procedure:1. Enter — 19998 a

Strona 42 - Typical Uses of Your Scale

Setra Super CountTM Operator's Manual 47The following table lists additional identification fields: ASCII Hexadecimal Equivalent ID F

Strona 43

48 Setra Super CountTM Operator's Manualing is a list of all possible mode characters:CHARACTER MEANING(space) Number field is a message or

Strona 44 - Glossary of Terms

Setra Super CountTM Operator's Manual 49To read data that may be stored in a specific memory register, you must first instruct the sc

Strona 45 - Appendix VI

Setra Super CountTM Operator's Manual 5Section TwoUnderstanding Your ScaleKEYBOARD FUNCTIONSzero Assigns the pan and whatever is curr

Strona 46

50 Setra Super CountTM Operator's ManualThe Jump Function causes the scale to immediately operate in a given weight unit. Using this functio

Strona 47

Setra Super CountTM Operator's Manual 51Although Setra scales can communicate with almost any RS-232 device, the built-in interface d

Strona 48

52 Setra Super CountTM Operator's Manualscale units to grams, e) set the ID to ABC-123, f) read the ID back from the scale and g) wait for a

Strona 49 - The Jump Function

Setra Super CountTM Operator's Manual 53Appendix VIIAccessories and OptionsThe following accessories are available for the Setra Supe

Strona 50 - The RS-232 Interface Hardware

54 Setra Super CountTM Operator's ManualAppendix VIIIIn Case of DifficultyIf you have reached a state in which the scale will no longer foll

Strona 51

Setra Super CountTM Operator's Manual 55If the RS-232 interface does not function correctly, first check that the correct RS-232 cabl

Strona 52

56 Setra Super CountTM Operator's ManualAppendix IXBattery OptionInstallationDisassembly of the entire scale is not required when installing

Strona 53 - Accessories and Options

Setra Super CountTM Operator's Manual 57Battery Use for Portable OperationA fully charged battery will allow a Setra scale to operate

Strona 54 - In Case of Difficulty

58 Setra Super CountTM Operator's Manual Appendix XSpecificationsSetra SUPER COUNT™CAPACITY REPRODUCIBILITY READABILITY NON-LINEARITY2.

Strona 55

Setra Super CountTM Operator's Manual 59Selectable Parity: even/odd/noneDisplay: 6-digit LCDPan: Stainless SteelOperating Temperature

Strona 56 - Battery Option

6 Setra Super CountTM Operator's Manual— Instructs scale to change the sign of a number. Interpreted as a hyphen whenentered as part of an I

Strona 57 - Battery Charging

60 Setra Super CountTM Operator's ManualAppendix XIScript Codes for Keypad EntryThe following tables show the codes for the ASCII characters

Strona 58 - Specifications

Setra Super CountTM Operator's Manual 61Punctuation and Special Characters!33 [91“34 \92#35 ] 93$36 ^94%37 —95&38 ‘ 96‘ 39 { 123(

Strona 59

62 Setra Super CountTM Operator's ManualSetra Scale DataID 0 128 transmit ID field 0 “S” idID 1 129 transmit ID field 1 “D” idID 2 130 trans

Strona 60 - Script Codes for Keypad Entry

Setra Super CountTM Operator's Manual 63Format CodesFormat Length 160 Set the length of the field to be printed.(Argument code 1 to 9

Strona 61

64 Setra Super CountTM Operator's ManualASCII Control Characterssoh 1 ctrl A esc 27stx 2 ctrl B fs 28etx 3 ctrl C gs 29eot 4 ctrl D rs 30enq

Strona 62

Setra Super CountTM Operator's Manual 65Appendix XIISetra Systems, Inc.Limited Two-Year Scale WarrantySetra Systems, Inc. warrants th

Strona 63

66 Setra Super CountTM Operator's ManualINDEX01oF01 28AC adaptor 3, 18, 59accessories 53accum 5, 6, 15, 22, 23, 24, 31, 34, 45, 48accumulate

Strona 64

Setra Super CountTM Operator's Manual 67accum 16Clear To Send 51code 24, 26, 49, 60format 63sequence 24CodES 27CompuCount™ 25computer

Strona 65 - Setra Systems, Inc

68 Setra Super CountTM Operator's Manualgross weight 5, 6, 8, 12, 31, 34, 44, 45, 48, 49handshaking 31, 45, 51hardware 45, 51hexadecimal 45,

Strona 66

Setra Super CountTM Operator's Manual 69NO LOC 19, 20, 21, 39non-linearity 58OFLO 7OK 6, 8, 10, 11, 12, 13, 14, 29, 48ounces 5, 6, 8,

Strona 67

Setra Super CountTM Operator's Manual 7DISPLAY MESSAGESC nnn g Displayed when the scale is powered on and when the reset key is press

Strona 68

70 Setra Super CountTM Operator's Manualsample 5, 8, 11, 14, 32, 44custom 11sample size 9, 10, 11, 12, 14, 15, 43, 45minimum (See minimum sa

Strona 69

Setra Super CountTM Operator's Manual 71to order 53transmission sequence 26troy ounces 6, 8, 37, 48, 50, 58typographical conventions

Strona 70

72 Setra Super CountTM Operator's ManualFCC WARNINGThis equipment has been tested and found to comply with the limits for a Class A digital

Strona 71

Setra Super CountTM Operator's Manual 73

Strona 72

8 Setra Super CountTM Operator's ManualSection ThreeUsing Your ScaleBASIC WEIGHINGTo weigh a sample on your scale, use the following procedu

Komentarze do niniejszej Instrukcji