Super IISupervisor and TechnicalManualSetra Systems, IncWeighing Systems Division159 Swanson RoadBoxborough, MA 01719TMTDSS2068-01 Rev D 12/01
Supervisor Setup • Super II 10Enter label name Download “Script” or enter codesLABEL/PAPER as stored in printer through
Appendix A • Super II 100FUNCTIONAPWID 7COUNTID 1exponentialID9GROSS/NET toggleID 6integration filterjump codeCLEARID 3ACCUMULA
Appendix A • Super II 101Never include a carriage return or line feed in any command sequence. The scale uses any commandcharact
Appendix A • Super II 102Receiving Data From the Scale Using the Immediate Print ModeThe immediate print command “#” causes the
Appendix A • Super II 103“c3” is the “stability” character. This character corresponds to the “OK” symbol on the display.CHARACT
Appendix A • Super II 104To use the Jump Function, send an nJ to the scale, where “J” is the Jump function command and “n” is t
Appendix A • Super II 105The RS232 Interface HardwareAlthough Setra scales can communicate with almost any RS232 device, the bui
Appendix B • Super II 106Appendix BScriptCoderTM Custom Label PrintingYour Super II scale can be programmed to print custom l
Appendix B • Super II 107To produce the ASCII output below, enter the following script by using the numeric keypad followed byt
Appendix B • Super II 108Part #: 123-456APW: 2.56789 gSCRIPT - Part #: (ID 0 is default register) <CR><LF>QWERTY K
Appendix B • Super II 109The following tables show the codes for the ASCII characters, ASCII control codes and Setra scale data
Supervisor Setup • Super II 11Soft Key:PRINT SETUPSetting Print Formats or Print IntervalThis setup allows for the design of up to ten differe
Appendix B • Super II 110Punctuation and Special Characters!33 [91“34 \92#35 ] 93$36 ^94%37 —95&38 ‘ 96‘ 39 { 123( 40 | 12
Appendix B • Super II 111Setra Scale DataID 0 128 transmit ID field 0 “S” idID 1 129 transmit ID field 1 “D” idID 2 130 transmi
Appendix B • Super II 112Format CodesFormat Length 160 Set the length of the field to be printed.(Argument code 1 to 99.)Forma
Appendix B • Super II 113ASCII Control Characterssoh 1 ctrl A esc 27stx 2 ctrl B fs 28etx 3 ctrl C gs 29eot 4 ctrl D rs 30enq 5
Appendix C • Super II 114PANPAN SUPPORTBASEBUBBLE LEVELLOAD CELLMODULETRANSPORTATIONHOLDER FOR THEAC ADAPTERPAN SUPPORTSTOPSFi
Appendix C • Super II 115Battery Use for Portable OperationA fully charged battery will allow the Setra Super II to operate fo
Appendix D • Super II 116PANPAN SUPPORTBASELOAD CELLMODULEFigure 1. Exploded view of Super II bef ore Remote Scale Option Ins
Appendix D • Super II 117Connector WiringIf the cable connector of the remote scale base is physically compatible with the 6 p
Appendix D • Super II 1185. Fold back the shield and strip 1/10" from each wire.Figure 3. Cable Preparation6. Following t
Appendix D • Super II 119CalibrationThe calibration of the Strain Gauge Load Cell Remote Scale Option is accessed through the
Supervisor Setup • Super II 12Select the function to program:PRINT FORMATS allows the print registers to be configured..PRINT INTRVL allows programm
Appendix D • Super II 120Enter the desired display resolution increment in the selected weightunit and press ENTER.Note: The
Appendix D • Super II 121Wait while a stable weight reading is acquired.Remove all weight from the scale pan and press ENTER.W
Appendix E • Super II 122Appendix ESPECIFICATIONSCAPACITY READABILITY REPRODUCIBILITY NON-LINEARITY2
Appendix E • Super II 123CONTROLLERDisplay type: Display units:Display resolution:Display update rate:I
Appendix E • Super II 124PAN Construction:Dimensions:(25 - 50 kg)(12 - 16 kg)DIMENSIONSOverall:(25 - 50 kg)(12 - 16 kg)With con
Appendix F • Super II 125Appendix FGlossary of TermsAccuracy
Appendix F • Super II 126Macro A series of preprogrammed scale functions that are initiated by a keypress, and bymeans of display prompts, wi
Appendix G • Super II 127Appendix G Setra Systems, Inc.Limited Two-Year Scale WarrantySetra Systems, Inc. warrants the scal
Appendix H • Super II 128Appendix HWARNINGSWARNING: IF THIS EQUIPMENT IS USED IN A MANNER NOT SPECIFIED BY THEMANUFACTURER, T
FCC WarningThis equipment has been tested and found to comply with the limits for a Class A digitaldevice pursuant to Part 15 of FCC Rules. These limi
Supervisor Setup • Super II 13Based on the print format type selected, one of three series of screens appears:DYMO®* Setra 300/COSTARA. Select
EC Declaration of ConformityThe product manufacturer,Setra Systems, Inc.159 Swanson RoadBoxborough, Massachusetts 01719U.S.A.declares under its sole r
Index • Super II 1316 Pin circular DIN Connector 118Aabc key 40, 73AC adapter 114, 115ACCUM 45ACCUMULATE 100A
Index • Super II 132Graphics LCD 123GREETING 8, 72, 73, 95, 97Greeting Message 73Gross Weight 125GROSS/NET toggle 100Hhandshaking 99hardware
Index • Super II 133RESOLUT 8, 61Resolution 29, 61,126counting 125displayed 125RESTART 45REV 39RS-232 23, 9
Supervisor Setup • Super II 14D. After selecting and formatting all of the desired fields, select the DONE soft key at theend of the field selection
Supervisor Setup • Super II 15Selecting Fields to PrintThe following is a list of all scale fields available for printing. The fields can be p
Supervisor Setup • Super II 16ID FieldsID field selection will bring up the following menu.Select the desired ID field to print by entering the nume
Supervisor Setup • Super II 17NO FRMT GO BACK Select Format for Interval Printing: 0. Print 0
Supervisor Setup • Super II 18Supervisor Setup Menu: Soft Key SAMPLE SETUPSAMPLE SETUP ENTER SAMPLE # IN MENU GO BACKUsing the numeric keypad,t
Supervisor Setup • Super II 19 abc resetmenu remotetareSETUPS MORESUPERSETUP SAMPLE SETUPSoft Key:SAMPLE SETUPSetting a Minimum Samp
Table of ContentsIntroduction ...
Supervisor Setup • Super II 20Supervisor Setup Menu: Soft Key ACCURCY SETUPACCURACY SETUP ENTER 95% 98% 99% MOREUsing numeric keypad, type in
Supervisor Setup • Super II 21SETUPS MORESUPERSETUP abc reset taremenu remote ACCURCY SETUPSoft Key:ACCURCY SETUPSetting a Minim
Supervisor Setup • Super II 22Supervisor Setup Menu: Soft Key PORTS SETUPPORTSSETUP BI* OUT IN GO BACKB9600
Supervisor Setup • Super II 23SETUPS MORESUPERSETUPPORTSSETUP abc reset taremenu remoteSoft Key:PORTS SETUPProgramming the RS232 Sett
Supervisor Setup • Super II 24 DATE TIME SET SET GO BACKFORMAT FORMAT DATE TIME Enter date Enter time MM.DD.YY HH.MMSupervisor S
Supervisor Setup • Super II 25 abc resetmenu remotetareSETUPS MORESUPERSETUPMORE TIME DATESoft Key:TIME DATEProgramming the Time Dat
Supervisor Setup • Super II 26Set the date using the format MM.DD.YY ENTER GO BACKSelect the disp
Supervisor Setup • Super II 27Supervisor Setup Menu: Soft Key UNITS ENABLED Enter name for Enter resolution user definable unit
Supervisor Setup • Super II 28SETUPS MORESUPERSETUP abc reset taremenu remote UNITS ENABLED MORESoft Key:UNITS ENABLEDSelecting Weighing
Supervisor Setup • Super II 29Enter the details of the selected unit:CONVRSN NAME RESOLUT ON/OFF GO BACK FACTOR DIVISOR GO
Soft Key: AUTO SWITCH ... 84Soft Key: ALARMS...
Supervisor Setup • Super II 30Supervisor Setup Menu: Soft Key DATBASE SETUPDATABASESETUP PART ID, APW, TARE PART ID, LOT #, APW
Supervisor Setup • Super II 31SETUPS MORESUPERSETUP abc reset taremenu remote DATBASE SETUP MORESoft Key:DATBASE SETUPSetting up
Supervisor Setup • Super II 32 DATBASE PRINT DATBASE GO BACK FORMAT TRANSFR SECURTYSelect database setup option: 5
Supervisor Setup • Super II 33Select the database protection from themenu below: LOCK OLD NO LOCK LOCK ALL GO BACKSelect
Supervisor Setup • Super II 34TURN TL CHOOSE PRINT
Supervisor Setup • Super II 35SETUPS MORESUPERSETUP abc reset taremenu remote TRANSAC SETUP MORESelect TL fields using the numer
Supervisor Setup • Super II 36Select TL fields using the numeric keys: 1. PART ID 4. OPRTR 2. LOT # 5. COUNT 3. DESC. 6. TIME/DATETURN TL CHOOSE
Supervisor Setup • Super II 37 The following menu appears:Select a port. The following menu appears:Choose a print format and the data will be
Supervisor Setup • Super II 38Supervisor Setup Menu: Soft Key ID NAME SETUPID NAMESETUPID0: PART ID ID4: DESC ID8:ID1: OPRTR ID5: VENDOR ID9:ID2:
Supervisor Setup • Super II 39Soft Key:ID NAME SETUPChanging the Name of the ID FieldsThis setup allows changes to be made to the name of the
Introduction • Super II 4Introduction
Supervisor Setup • Super II 40The following menu will appear:Using the numeric keypad, enter the number of the desired ID field name to be changed.U
Supervisor Setup • Super II 41Supervisor Setup Menu: Soft Key MACRO SETUP0. Macro 4. Macro 4 8. Macro 81. Macro 1 5. Macro 5 9. Example2. M
Supervisor Setup • Super II 42SETUPS MORESUPERSETUP abc reset taremenu remote MACRO SETUP MORE MORE GO BACK 0. Macro 0 4. Macro 4
Supervisor Setup • Super II 43Once the macro position has been selected, the soft keys change to the following:NAME/RENAME To customize the n
Supervisor Setup • Super II 44A. To use the default prompt, press the STANDRD PROMPT soft key and the program will return to thescale function selec
Supervisor Setup • Super II 45MACRO STEPS:NAME FUNCTION PROMPTZERO Zeros any weight on the scale Zero the scale by pressing the ZERO key.TARE
Supervisor Setup • Super II 46 GO BACK Select the base to switch to. 1. Base 1 5. Ba
Supervisor Setup • Super II 47Supervisor Setup Menu: Soft Key SETUP SECURTY SETUPSECURITY ENTER GO BACK
Supervisor Setup • Super II 48Soft Key:SETUP SECURTYSetting Supervisor Password ProtectionThis setup allows the set up of password protection for th
Supervisor Setup • Super II 49Supervisor Setup Menu: Soft Key BEEPER CONTROL BEEPERCONTROLON OFFGO BACK
Introduction • Super II 5IntroductionFor many counting or weighing applications, the Super II default s
Supervisor Setup • Super II 50SETUPS MORESUPERSETUP abc reset taremenu remote MORE MORE MORE BEEPER CONTROLSoft Key:BEEPER CONTROLSett
Bases Setup • Super II
Bases Setup • Super II 52Bases Setup Menu: Soft Key CALIBCALIB ZERO SPAN GO BACK Zero scale, recommen
Bases Setup • Super II
Bases Setup • Super II 54The soft keys will change to the following:For the best results, the span weight should be as close as possible to th
Bases Setup • Super II
Bases Setup • Super II 56Bases Setup Menu: Soft Key SPEEDSPEED FASTEST FAST DEFAULT SLOW SLOWEST1. BASE 1 5. BASE 52. BASE 2 6. BASE
Bases Setup • Super II
Bases Setup • Super II 58Bases Setup Menu: Soft Key ZERO1. BASE 1 5. BASE 52. BASE 2 6. BASE 63. BASE 3 7. BASE 74. BASE 4 8. BASE 8
Bases Setup • Super II
Introduction • Super II 6Prompting MacrosThe scale’s display can prompt a user through a series of steps for repetitive tasks. The macros are easi
Bases Setup • Super II 60Bases Setup Menu: Soft Key RESOLUT USER DEFAULT
Bases Setup • Super II
Bases Setup • Super II 62Bases Setup Menu: Soft Key INFO INFO1. BASE 1 5. BASE 52. BASE 2 6. BASE 63. BASE 3 7. BASE 74. BASE 4 8. BAS
Bases Setup • Super II
Bases Setup • Super II 64Bases Menu: Soft Key NAME ENTER
Bases Setup • Super II
Bases Setup • Super II 66Bases Menu: Soft Key ADDRESSADDRESS GO BACK1. BASE 1 5. BASE 52. BASE 2 6. BASE 63. BASE 3 7. BASE 74. BASE 4
Bases Setup • Super II
Bases Setup • Super II 687. Using the numeric keypad, select the base address to reassign.8. Using the numeric keypad, select the new address
Bases Setup • Super II
Introduction • Super II 7TRANSAC Activate and choose the fields to record in the transaction log, print
Bases Setup • Super II 70SETUPS MOREBASESSETUPMORE abc reset taremenu remoteBASERSTSoft Key:BASERSTResetting the BaseThere may be tim
Technical Setup • Super II
Technical Setup • Super II 72Technical Setup Menu: Soft Key GREETNGLINE 1 LINE 2 LINE 3 LINE 4 GO BACK GREETINGType in inform
Technical Setup • Super II
Technical Setup • Super II 74Technical Setup Menu: Soft Key BACKLITBAT LIM DELAY ON INPT GO BACKBACKLITEnter maximum backlight
Technical Setup • Super II
Technical Setup • Super II 76Select backlight battery powermanagement value to set:Battery brightness limit: 6Shut-off del
Technical Setup • Super II
Technical Setup • Super II 78Select the setups to transfer: BASIC MACRO PRINT BASES GO BACK SETUPS SETUPS
Technical Setup • Super II
Introduction • Super II 8ALARMS Configure and enable/disable the digital output alarms.DIG INP Set up the controller for control by outside equipme
Technical Setup • Super II 80FACDEF CLEAR CLEAR CLEAR GO BACKDB PRINT MACROTechnical Setup Menu: Soft Key RESETRESET
Technical Setup • Super II
Technical Setup • Super II 82 CLEAR CLEAR GO BACK ALL COUNTSelect from the database clearing optionsl
Technical Setup • Super II
Technical Setup • Super II 84Technical Setup Menu: Soft Key AUTO SWITCH AUTOSWITCH COUNT SAMPLEAUTOSWT AUTOSWT GO BACKAutom
Technical Setup • Super II
Technical Setup • Super II 86Technical Setup Menu: Soft Key ALARMSALARMSENABLE DISABLE PROGRAM GO BACKALARM 1
Technical Setup • Super II
Technical Setup • Super II 88LOW TARGET HIGH LATCHALARM 1 LO HI HI HIALARM 2 LO LO HI HIALARM 3 LO LO LO
Technical Setup • Super II
Supervisor Setup • Super II 9 Supervisor Setup
Technical Setup • Super II 90Technical Setup Menu: Soft Key DIG INPDIG INPINPUT 1 INPUT 2 GO BACKNONE GO
Technical Setup • Super II
Technical Setup • Super II 92Technical Setup Menu: Soft Key SETUP SECURTY SETUPSECURTY ENTER GO BACK
Technical Setup • Super II
Technical Setup • Super II 94Technical Setup Menu: Soft Key HYSTERSHYSTERS ON OFF GO BACK
Technical Setup • Super II
Technical Setup • Super II 96Technical Setup Menu: Soft Key APW QTYMODE 1 MODE 2 MODE 3 SET NO. GO BACKPIECES APW QTY
Technical Setup • Super II
Technical Setup • Super II 98The following screen and soft keys will be displayed:Select the APW quantity mode desired using t
Appendix A • Super II 99Appendix ARS232 Serial Port CommunicationsThe Super II comes equipped with three RS232 ports. They are
Komentarze do niniejszej Instrukcji