Setra Systems 12000C Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Wagi kuchenne Setra Systems 12000C. Setra Systems 12000C Specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 133
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Super II
Supervisor and Technical
Manual
Setra Systems, Inc
Weighing Systems Division
159 Swanson Road
Boxborough, MA 01719
TM
TDSS2068-01 Rev D 12/01
Przeglądanie stron 0
1 2 3 4 5 6 ... 132 133

Podsumowanie treści

Strona 1 - Super II

Super IISupervisor and TechnicalManualSetra Systems, IncWeighing Systems Division159 Swanson RoadBoxborough, MA 01719TMTDSS2068-01 Rev D 12/01

Strona 2 - Table of Contents

Supervisor Setup • Super II 10Enter label name Download “Script” or enter codesLABEL/PAPER as stored in printer through

Strona 3

Appendix A • Super II 100FUNCTIONAPWID 7COUNTID 1exponentialID9GROSS/NET toggleID 6integration filterjump codeCLEARID 3ACCUMULA

Strona 4 - Introduction

Appendix A • Super II 101Never include a carriage return or line feed in any command sequence. The scale uses any commandcharact

Strona 5

Appendix A • Super II 102Receiving Data From the Scale Using the Immediate Print ModeThe immediate print command “#” causes the

Strona 6 - • Super II 6

Appendix A • Super II 103“c3” is the “stability” character. This character corresponds to the “OK” symbol on the display.CHARACT

Strona 7

Appendix A • Super II 104To use the Jump Function, send an nJ to the scale, where “J” is the Jump function command and “n” is t

Strona 8 - • Super II 8

Appendix A • Super II 105The RS232 Interface HardwareAlthough Setra scales can communicate with almost any RS232 device, the bui

Strona 9 - Supervisor Setup

Appendix B • Super II 106Appendix BScriptCoderTM Custom Label PrintingYour Super II scale can be programmed to print custom l

Strona 10 - • Super II 10

Appendix B • Super II 107To produce the ASCII output below, enter the following script by using the numeric keypad followed byt

Strona 11 - PRINT SETUP

Appendix B • Super II 108Part #: 123-456APW: 2.56789 gSCRIPT - Part #: (ID 0 is default register) <CR><LF>QWERTY K

Strona 12 - Programming a PRINT Format

Appendix B • Super II 109The following tables show the codes for the ASCII characters, ASCII control codes and Setra scale data

Strona 13 - * Setra 300/COSTAR

Supervisor Setup • Super II 11Soft Key:PRINT SETUPSetting Print Formats or Print IntervalThis setup allows for the design of up to ten differe

Strona 14 - • Super II 14

Appendix B • Super II 110Punctuation and Special Characters!33 [91“34 \92#35 ] 93$36 ^94%37 —95&38 ‘ 96‘ 39 { 123( 40 | 12

Strona 15 - Selecting Fields to Print

Appendix B • Super II 111Setra Scale DataID 0 128 transmit ID field 0 “S” idID 1 129 transmit ID field 1 “D” idID 2 130 transmi

Strona 16 - ID Fields

Appendix B • Super II 112Format CodesFormat Length 160 Set the length of the field to be printed.(Argument code 1 to 99.)Forma

Strona 17 - Interval Print Programming

Appendix B • Super II 113ASCII Control Characterssoh 1 ctrl A esc 27stx 2 ctrl B fs 28etx 3 ctrl C gs 29eot 4 ctrl D rs 30enq 5

Strona 18 - • Super II 18

Appendix C • Super II 114PANPAN SUPPORTBASEBUBBLE LEVELLOAD CELLMODULETRANSPORTATIONHOLDER FOR THEAC ADAPTERPAN SUPPORTSTOPSFi

Strona 19 - SAMPLE SETUP

Appendix C • Super II 115Battery Use for Portable OperationA fully charged battery will allow the Setra Super II to operate fo

Strona 20 - SETUP

Appendix D • Super II 116PANPAN SUPPORTBASELOAD CELLMODULEFigure 1. Exploded view of Super II bef ore Remote Scale Option Ins

Strona 21 - ACCURCY SETUP

Appendix D • Super II 117Connector WiringIf the cable connector of the remote scale base is physically compatible with the 6 p

Strona 22 - BI* OUT IN GO BACK

Appendix D • Super II 1185. Fold back the shield and strip 1/10" from each wire.Figure 3. Cable Preparation6. Following t

Strona 23 - PORTS SETUP

Appendix D • Super II 119CalibrationThe calibration of the Strain Gauge Load Cell Remote Scale Option is accessed through the

Strona 24 - 12 HR 24 HR

Supervisor Setup • Super II 12Select the function to program:PRINT FORMATS allows the print registers to be configured..PRINT INTRVL allows programm

Strona 25 - TIME DATE

Appendix D • Super II 120Enter the desired display resolution increment in the selected weightunit and press ENTER.Note: The

Strona 26 - • Super II 26

Appendix D • Super II 121Wait while a stable weight reading is acquired.Remove all weight from the scale pan and press ENTER.W

Strona 27 - UNITS

Appendix E • Super II 122Appendix ESPECIFICATIONSCAPACITY READABILITY REPRODUCIBILITY NON-LINEARITY2

Strona 28 - UNITS ENABLED

Appendix E • Super II 123CONTROLLERDisplay type: Display units:Display resolution:Display update rate:I

Strona 29 - NAME RESOLUT ON/OFF GO

Appendix E • Super II 124PAN Construction:Dimensions:(25 - 50 kg)(12 - 16 kg)DIMENSIONSOverall:(25 - 50 kg)(12 - 16 kg)With con

Strona 30 - DATABASE

Appendix F • Super II 125Appendix FGlossary of TermsAccuracy

Strona 31 - DATBASE SETUP

Appendix F • Super II 126Macro A series of preprogrammed scale functions that are initiated by a keypress, and bymeans of display prompts, wi

Strona 32 - 6. DATABASE OFF

Appendix G • Super II 127Appendix G Setra Systems, Inc.Limited Two-Year Scale WarrantySetra Systems, Inc. warrants the scal

Strona 33 - • Super II 33

Appendix H • Super II 128Appendix HWARNINGSWARNING: IF THIS EQUIPMENT IS USED IN A MANNER NOT SPECIFIED BY THEMANUFACTURER, T

Strona 34 - • Super II 34

FCC WarningThis equipment has been tested and found to comply with the limits for a Class A digitaldevice pursuant to Part 15 of FCC Rules. These limi

Strona 35 - TRANSAC SETUP

Supervisor Setup • Super II 13Based on the print format type selected, one of three series of screens appears:DYMO®* Setra 300/COSTARA. Select

Strona 36 - • Super II 36

EC Declaration of ConformityThe product manufacturer,Setra Systems, Inc.159 Swanson RoadBoxborough, Massachusetts 01719U.S.A.declares under its sole r

Strona 37 - • Super II 37

Index • Super II 1316 Pin circular DIN Connector 118Aabc key 40, 73AC adapter 114, 115ACCUM 45ACCUMULATE 100A

Strona 38 - ID3: LOT # ID7:

Index • Super II 132Graphics LCD 123GREETING 8, 72, 73, 95, 97Greeting Message 73Gross Weight 125GROSS/NET toggle 100Hhandshaking 99hardware

Strona 39 - ID NAME SETUP

Index • Super II 133RESOLUT 8, 61Resolution 29, 61,126counting 125displayed 125RESTART 45REV 39RS-232 23, 9

Strona 40 - ENTER

Supervisor Setup • Super II 14D. After selecting and formatting all of the desired fields, select the DONE soft key at theend of the field selection

Strona 41 - • Super II 41

Supervisor Setup • Super II 15Selecting Fields to PrintThe following is a list of all scale fields available for printing. The fields can be p

Strona 42 - MACRO SETUP

Supervisor Setup • Super II 16ID FieldsID field selection will bring up the following menu.Select the desired ID field to print by entering the nume

Strona 43 - Programming a Macro

Supervisor Setup • Super II 17NO FRMT GO BACK Select Format for Interval Printing: 0. Print 0

Strona 44 - • Super II 44

Supervisor Setup • Super II 18Supervisor Setup Menu: Soft Key SAMPLE SETUPSAMPLE SETUP ENTER SAMPLE # IN MENU GO BACKUsing the numeric keypad,t

Strona 45 - • Super II 45

Supervisor Setup • Super II 19 abc resetmenu remotetareSETUPS MORESUPERSETUP SAMPLE SETUPSoft Key:SAMPLE SETUPSetting a Minimum Samp

Strona 46 - • Super II 46

Table of ContentsIntroduction ...

Strona 47 - SECURITY

Supervisor Setup • Super II 20Supervisor Setup Menu: Soft Key ACCURCY SETUPACCURACY SETUP ENTER 95% 98% 99% MOREUsing numeric keypad, type in

Strona 48 - SETUP SECURTY

Supervisor Setup • Super II 21SETUPS MORESUPERSETUP abc reset taremenu remote ACCURCY SETUPSoft Key:ACCURCY SETUPSetting a Minim

Strona 49 - • Super II 49

Supervisor Setup • Super II 22Supervisor Setup Menu: Soft Key PORTS SETUPPORTSSETUP BI* OUT IN GO BACKB9600

Strona 50 - BEEPER CONTROL

Supervisor Setup • Super II 23SETUPS MORESUPERSETUPPORTSSETUP abc reset taremenu remoteSoft Key:PORTS SETUPProgramming the RS232 Sett

Strona 51 - Bases Setup

Supervisor Setup • Super II 24 DATE TIME SET SET GO BACKFORMAT FORMAT DATE TIME Enter date Enter time MM.DD.YY HH.MMSupervisor S

Strona 52 - • Super II 52

Supervisor Setup • Super II 25 abc resetmenu remotetareSETUPS MORESUPERSETUPMORE TIME DATESoft Key:TIME DATEProgramming the Time Dat

Strona 53

Supervisor Setup • Super II 26Set the date using the format MM.DD.YY ENTER GO BACKSelect the disp

Strona 54 - Select calibration option:

Supervisor Setup • Super II 27Supervisor Setup Menu: Soft Key UNITS ENABLED Enter name for Enter resolution user definable unit

Strona 55

Supervisor Setup • Super II 28SETUPS MORESUPERSETUP abc reset taremenu remote UNITS ENABLED MORESoft Key:UNITS ENABLEDSelecting Weighing

Strona 56 - 4. BASE 4 8. BASE 8

Supervisor Setup • Super II 29Enter the details of the selected unit:CONVRSN NAME RESOLUT ON/OFF GO BACK FACTOR DIVISOR GO

Strona 57 - Soft Key:

Soft Key: AUTO SWITCH ... 84Soft Key: ALARMS...

Strona 58 - • Super II 58

Supervisor Setup • Super II 30Supervisor Setup Menu: Soft Key DATBASE SETUPDATABASESETUP PART ID, APW, TARE PART ID, LOT #, APW

Strona 59

Supervisor Setup • Super II 31SETUPS MORESUPERSETUP abc reset taremenu remote DATBASE SETUP MORESoft Key:DATBASE SETUPSetting up

Strona 60

Supervisor Setup • Super II 32 DATBASE PRINT DATBASE GO BACK FORMAT TRANSFR SECURTYSelect database setup option: 5

Strona 61

Supervisor Setup • Super II 33Select the database protection from themenu below: LOCK OLD NO LOCK LOCK ALL GO BACKSelect

Strona 62

Supervisor Setup • Super II 34TURN TL CHOOSE PRINT

Strona 63

Supervisor Setup • Super II 35SETUPS MORESUPERSETUP abc reset taremenu remote TRANSAC SETUP MORESelect TL fields using the numer

Strona 64 - Bases Menu: Soft Key NAME

Supervisor Setup • Super II 36Select TL fields using the numeric keys: 1. PART ID 4. OPRTR 2. LOT # 5. COUNT 3. DESC. 6. TIME/DATETURN TL CHOOSE

Strona 65 - Changing the Name of a Base

Supervisor Setup • Super II 37 The following menu appears:Select a port. The following menu appears:Choose a print format and the data will be

Strona 66 - Bases Menu: Soft Key ADDRESS

Supervisor Setup • Super II 38Supervisor Setup Menu: Soft Key ID NAME SETUPID NAMESETUPID0: PART ID ID4: DESC ID8:ID1: OPRTR ID5: VENDOR ID9:ID2:

Strona 67

Supervisor Setup • Super II 39Soft Key:ID NAME SETUPChanging the Name of the ID FieldsThis setup allows changes to be made to the name of the

Strona 68 - • Super II 68

Introduction • Super II 4Introduction

Strona 69 - Bases Menu: Soft Key BASERST

Supervisor Setup • Super II 40The following menu will appear:Using the numeric keypad, enter the number of the desired ID field name to be changed.U

Strona 70 - Resetting the Base

Supervisor Setup • Super II 41Supervisor Setup Menu: Soft Key MACRO SETUP0. Macro 4. Macro 4 8. Macro 81. Macro 1 5. Macro 5 9. Example2. M

Strona 71 - Technical Setup

Supervisor Setup • Super II 42SETUPS MORESUPERSETUP abc reset taremenu remote MACRO SETUP MORE MORE GO BACK 0. Macro 0 4. Macro 4

Strona 72 - GREETING

Supervisor Setup • Super II 43Once the macro position has been selected, the soft keys change to the following:NAME/RENAME To customize the n

Strona 73 - Setting the Power-Up Greeting

Supervisor Setup • Super II 44A. To use the default prompt, press the STANDRD PROMPT soft key and the program will return to thescale function selec

Strona 74 - BAT LIM DELAY ON INPT GO BACK

Supervisor Setup • Super II 45MACRO STEPS:NAME FUNCTION PROMPTZERO Zeros any weight on the scale Zero the scale by pressing the ZERO key.TARE

Strona 75 - Backlighting of the Display

Supervisor Setup • Super II 46 GO BACK Select the base to switch to. 1. Base 1 5. Ba

Strona 76

Supervisor Setup • Super II 47Supervisor Setup Menu: Soft Key SETUP SECURTY SETUPSECURITY ENTER GO BACK

Strona 77 - TRANSFER

Supervisor Setup • Super II 48Soft Key:SETUP SECURTYSetting Supervisor Password ProtectionThis setup allows the set up of password protection for th

Strona 78 - SETUP TRANSFR

Supervisor Setup • Super II 49Supervisor Setup Menu: Soft Key BEEPER CONTROL BEEPERCONTROLON OFFGO BACK

Strona 79

Introduction • Super II 5IntroductionFor many counting or weighing applications, the Super II default s

Strona 80

Supervisor Setup • Super II 50SETUPS MORESUPERSETUP abc reset taremenu remote MORE MORE MORE BEEPER CONTROLSoft Key:BEEPER CONTROLSett

Strona 81

Bases Setup • Super II

Strona 82 - ALL COUNT

Bases Setup • Super II 52Bases Setup Menu: Soft Key CALIBCALIB ZERO SPAN GO BACK Zero scale, recommen

Strona 83

Bases Setup • Super II

Strona 84

Bases Setup • Super II 54The soft keys will change to the following:For the best results, the span weight should be as close as possible to th

Strona 85 - AUTO SWITCH

Bases Setup • Super II

Strona 86

Bases Setup • Super II 56Bases Setup Menu: Soft Key SPEEDSPEED FASTEST FAST DEFAULT SLOW SLOWEST1. BASE 1 5. BASE 52. BASE 2 6. BASE

Strona 88 - ALARM 2 LO LO HI HI

Bases Setup • Super II 58Bases Setup Menu: Soft Key ZERO1. BASE 1 5. BASE 52. BASE 2 6. BASE 63. BASE 3 7. BASE 74. BASE 4 8. BASE 8

Strona 89

Bases Setup • Super II

Strona 90 - INPUT 1 INPUT 2 GO BACK

Introduction • Super II 6Prompting MacrosThe scale’s display can prompt a user through a series of steps for repetitive tasks. The macros are easi

Strona 91 - Setting the Digital Inputs

Bases Setup • Super II 60Bases Setup Menu: Soft Key RESOLUT USER DEFAULT

Strona 92

Bases Setup • Super II

Strona 93

Bases Setup • Super II 62Bases Setup Menu: Soft Key INFO INFO1. BASE 1 5. BASE 52. BASE 2 6. BASE 63. BASE 3 7. BASE 74. BASE 4 8. BAS

Strona 94 - ON OFF GO BACK

Bases Setup • Super II

Strona 95 - Improving Display Stability

Bases Setup • Super II 64Bases Menu: Soft Key NAME ENTER

Strona 96 - APW QTY

Bases Setup • Super II

Strona 97

Bases Setup • Super II 66Bases Menu: Soft Key ADDRESSADDRESS GO BACK1. BASE 1 5. BASE 52. BASE 2 6. BASE 63. BASE 3 7. BASE 74. BASE 4

Strona 98 - APW PIECES: 1000

Bases Setup • Super II

Strona 99 - Appendix A

Bases Setup • Super II 687. Using the numeric keypad, select the base address to reassign.8. Using the numeric keypad, select the new address

Strona 101 - 101

Introduction • Super II 7TRANSAC Activate and choose the fields to record in the transaction log, print

Strona 102

Bases Setup • Super II 70SETUPS MOREBASESSETUPMORE abc reset taremenu remoteBASERSTSoft Key:BASERSTResetting the BaseThere may be tim

Strona 103 - The Jump Function

Technical Setup • Super II

Strona 104 - The Verify Function

Technical Setup • Super II 72Technical Setup Menu: Soft Key GREETNGLINE 1 LINE 2 LINE 3 LINE 4 GO BACK GREETINGType in inform

Strona 105 - The RS232 Interface Hardware

Technical Setup • Super II

Strona 106 - Custom Label Printing

Technical Setup • Super II 74Technical Setup Menu: Soft Key BACKLITBAT LIM DELAY ON INPT GO BACKBACKLITEnter maximum backlight

Strona 107

Technical Setup • Super II

Strona 108 - Entering a Script Using a PC

Technical Setup • Super II 76Select backlight battery powermanagement value to set:Battery brightness limit: 6Shut-off del

Strona 109

Technical Setup • Super II

Strona 110

Technical Setup • Super II 78Select the setups to transfer: BASIC MACRO PRINT BASES GO BACK SETUPS SETUPS

Strona 111

Technical Setup • Super II

Strona 112

Introduction • Super II 8ALARMS Configure and enable/disable the digital output alarms.DIG INP Set up the controller for control by outside equipme

Strona 113 - ASCII Control Characters

Technical Setup • Super II 80FACDEF CLEAR CLEAR CLEAR GO BACKDB PRINT MACROTechnical Setup Menu: Soft Key RESETRESET

Strona 114 - Battery Option

Technical Setup • Super II

Strona 115 - Figure 2

Technical Setup • Super II 82 CLEAR CLEAR GO BACK ALL COUNTSelect from the database clearing optionsl

Strona 116 - Appendix D

Technical Setup • Super II

Strona 117

Technical Setup • Super II 84Technical Setup Menu: Soft Key AUTO SWITCH AUTOSWITCH COUNT SAMPLEAUTOSWT AUTOSWT GO BACKAutom

Strona 118 - Figure 3. Cable Preparation

Technical Setup • Super II

Strona 119 - Calibration

Technical Setup • Super II 86Technical Setup Menu: Soft Key ALARMSALARMSENABLE DISABLE PROGRAM GO BACKALARM 1

Strona 120

Technical Setup • Super II

Strona 121 - Press END

Technical Setup • Super II 88LOW TARGET HIGH LATCHALARM 1 LO HI HI HIALARM 2 LO LO HI HIALARM 3 LO LO LO

Strona 122 - SPECIFICATIONS

Technical Setup • Super II

Strona 123 - 123

Supervisor Setup • Super II 9 Supervisor Setup

Strona 124 - • Super II 124

Technical Setup • Super II 90Technical Setup Menu: Soft Key DIG INPDIG INPINPUT 1 INPUT 2 GO BACKNONE GO

Strona 125 - Glossary of Terms

Technical Setup • Super II

Strona 126 - • Super II 126

Technical Setup • Super II 92Technical Setup Menu: Soft Key SETUP SECURTY SETUPSECURTY ENTER GO BACK

Strona 127 - Setra Systems, Inc

Technical Setup • Super II

Strona 128 - WARNINGS

Technical Setup • Super II 94Technical Setup Menu: Soft Key HYSTERSHYSTERS ON OFF GO BACK

Strona 129 - FCC Warning

Technical Setup • Super II

Strona 130 - EC Declaration of Conformity

Technical Setup • Super II 96Technical Setup Menu: Soft Key APW QTYMODE 1 MODE 2 MODE 3 SET NO. GO BACKPIECES APW QTY

Strona 131

Technical Setup • Super II

Strona 132 - Index • Super II

Technical Setup • Super II 98The following screen and soft keys will be displayed:Select the APW quantity mode desired using t

Strona 133

Appendix A • Super II 99Appendix ARS232 Serial Port CommunicationsThe Super II comes equipped with three RS232 ports. They are

Komentarze do niniejszej Instrukcji